161
Custom Tone-Pair Settings Definitions
Field Name Values Description
Cadence 1 integer time
value in
milli-seconds;
zero value for
dial-tone
indicates
continuous tone
On/off pattern of tone durations
used to denote phone ringing,
phone busy, dial tone (“0”
indicates continuous tone)
survivability and re-order.
Cadence 1 is duration of first
period of tone being “on” in the
cadence of the telephony signal
(which could be ring-tone, busy-
tone, unobtainable-tone, or dial
tone).
Cadence 2 duration in
milliseconds
Cadence 2 is duration of first
“off” period in signaling
cadence.
Cadence 3 duration in
milliseconds
Cadence 3 is duration of second
“on” period in signaling cadence.
Cadence 4 duration in
milliseconds
Cadence 4 is duration of second
“off” period in the signaling
cadence, after which the 4-part
cadence pattern of the telephony
signal repeats.