E&M Interface Parameter Definitions (cont’d)
Field Name Values Description
Dialing Options (cont’d)
Flash Hook Options fields
Generation integer values, in
milliseconds
Length of flash hook that will
be generated and sent out when
the remote end initiates a flash
hook and it is regenerated
locally. Default = 600 ms.
Detection
Range
for Min. and Max.,
50 1500
milliseconds
For a received flash hook to be
regarded as such by the
MultiVOIP, its duration must
fall between the minimum and
maximum values given here.