Multi-Tech Systems MVP210-SS User Manual Page 148

  • Download
  • Add to my manuals
  • Print
  • Page
    / 415
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 147
Technical Configuration MultiVOIP User Guide
148
DID Interface Parameter Definitions (
cont’d)
Field Name Values Description
DID Options (cont’d)
Start Modes Immediate Start,
Wink Start,
Delay Dial
For Wink Start, the voip detects
the off-hook condition. Then
the voip reverses battery
polarity for a specified time
(140-290 ms; a “wink”) and then
becomes ready to receive dial
digits.
For Delay Dial, the voip detects
detects the off-hook condition.
Then the voip reverses battery
polarity for a specified time
(reverse polarity duration has
wider acceptable range than for
Wink Start) and then becomes
ready to receive dial digits.
Wink Timer
(in ms)
integer values,
in milliseconds
This is the length of the wink
for Wink Start and Delay Dial
signaling modes..
Applicable only when Start
Mode parameter is set to “Wink
Start” or “Delay Dial.”
Dialing Options
Inter Digit
Timer
integer values,
in seconds
This is the length of time that
the MultiVOIP will wait
between digits. When the time
expires, the MultiVOIP will
look in the phonebook for the
number entered.
Default = 2.
Message
Waiting
Indication
-- Not applicable to DID-DPO
interface.
Inter-Digit
Regeneration
Timer
integer values,
in milliseconds
This parameter is applicable
when digits are dialed onto a
DID-DPO channel after the
connection has been made. The
length of time between the
outputting of DTMF digits.
Default = 100 ms.
Page view 147