134
FXO Interface: Parameter Definitions*
Field Name Values Description
Interface Type FXO Enables FXO functionality
Dialing Options
Regeneration Pulse, DTMF Determines whether digits
generated and sent out will be
pulse tones or DTMF.
Inter Digit
Timer
1 to 10 seconds This is the length of time that
the MultiVOIP will wait
between digits. When the time
expires, the MultiVOIP will
look in the phonebook for the
number entered.
Default = 2.
Message
Waiting
Indication
-- Not applicable to FXO interface.
Inter Digit
Regeneration
Time
50 to 20,000
milliseconds
The length of time between the
outputting of DTMF digits.
Default = 100 ms.
FXO Options
FXO Ring
Count
1-99 Number of rings required
before the MultiVOIP answers
the incoming call.
No Response
Timer
1 – 65535
(in seconds)
Length of time before call
connection attempt is
abandoned.
Page view 133