“Regional Parameter” Definitions (cont’d)
Field Name Values Description
Country
Selection for
Built-In
Modem
(not applicable
to MVP-
130/130FXS
MVP210,
MVP410ST, or
MVP810ST)
country name
MultiVOIP units operating with the
X.06 software release (and above)
include a built-in modem. The
administrator can dial into this modem
to configure the MultiVOIP unit
remotely. The country name values in
this field set telephony parameters that
allow the modem to work in the listed
country. This value may be different
than the Country/Region value. For
example, a user may need to choose
“Europe” as the Country/Region value
but “Denmark” as the Country-
Selection-for-Built-In-Modem value.
User Defined Tones fields
Type column alphanumeric
name specified
by user
Name of supervisory tone pair.
Cannot be same as name of any
standard tone pair.
Frequency 1 freq. in Hertz Lower frequency of pair.
Frequency 2 freq. in Hertz
Higher frequency of pair.
Gain 1 gain in dB
+3dB to –31dB
and “mute” setting
Amplification factor of lower
frequency of pair.
This applies to any supervisory tones
that the MultiVOIP outputs as audio to
the FXS, FXS, or E&M port.
Default: -
16dB
Gain 2 gain in dB
+3dB to –31dB
and “mute” setting
Amplification factor of higher
frequency of pair.
This applies to any supervisory tones
that the MultiVOIP outputs as audio to
the FXS, FXO, or E&M port.
Default: -
16dB
Cadence
(msec) On/Off
n/n/n/n
four integer time
values in
milli-seconds;
zero value for
dial-tone
indicates
continuous tone
On/off pattern of tone durations used
to denote supervisory tones specified
by user. Supervisory tones relate to
answering and disconnection of calls.
Although most cadences have only two
parts (an “on” duration and an “off”
duration), some telephony cadences
have four parts. Most cadences, then,
are expressed as two iterations of a two-
part sequence. Although this is
redundant, it is necessary to allow for
expression of 4-part cadences.