MultiVOIP User Guide Technical Configuration
14
7
DID Parameters. The parameters applicable to the Direct Inward Dial
(DID) telephony interface type are shown in the figure below and
described in the table that follows. The DID interface allows one phone
line to direct incoming calls to any one of several extensions without a
switchboard operator. Of course, one DID line can handle only one call
at a time. The parameters described here pertain to the customer-
premises side of the DID connection (DID-DPO, dial-pulse originating);
the network side of the DID connection (DID-DPT, dial-pulse
terminating) is not supported.
DID Interface Parameter Definitions
Field Name Values Description
Interface DID-DPO Enables the customer-premises
side of DID functionality
DID Options MultiVOIP’s use of DID applies
only for incoming DID calls.
The Start Mode used by the
MultiVOIP must match that
used by the originating
telephony equipment, else DID
calls cannot be completed.
Start Modes Immediate Start,
Wink Start,
Delay Dial
For Immediate Start, the voip
detects the off-hook condition
initiated by the telco central-
office call and becomes ready to
receive dial digits immediately.
Page view 146