4 AT Commands, S-Registers, and Result Codes
51
S36 decimal 07 7 LAPM Failure Control. Specifies the fall-
back action to take in the event of an LAPM
negotiation failure. These fallback options
are initiated immediately upon connection
if S48 is set to 128. If an invalid number is
entered, S36 acts as if the default value has
been entered. (See S48.)
0 Modem disconnects.
1 Modem stays online and a direct mode
connection is established.
2 Reserved.
3 Modem stays on-line and a normal
mode connection is established.
4 An MNP connection is attempted and
if it fails, the modem disconnects.
5 An MNP connection is attempted and
if it fails, a direct mode connection is
established.
6 Reserved.
7 An MNP connection is attempted and
if it fails, a normal modem connection
is established.
S37 decimal 012 0 Sets the maximum V.34 speed at which the
modem attempts to connect. The default
value attempts an automode connection. If
N0 is active, connection is attempted at the
most recently sensed serial port speed
(+MS= command settings are updated to
the appropriate values). If N1 is active,
connection is attempted at the highest possi-
ble speed. (+MS= settings are updated to
11,1,300,33600 to reflect V.34, automode,
300 bps minimum speed, and 33600 bps
maximum speed). Supported only for com-
patibility with existing software; use the
+MS= command instead.
S38 seconds 0254, 255 20 Sets the delay between the modems receipt of
the H command to disconnect (or high-to-
low transition of DTR if the modem is pro-
grammed to follow the signal), and the
disconnect operation. Applies only to error-
correction connections. This register can be
used to ensure that data in the modem buffer
is sent before the modem disconnects. If S38
is set to a value between 0 and 254, the
modem waits for the remote modem to ac-
knowledge all data in the modem buffer
before disconnecting. If S38 is set to 255, the
modem does not time out, and continues to