Multi-Tech Systems S000573A User Manual Page 14

  • Download
  • Add to my manuals
  • Print
  • Page
    / 38
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 13
UsingtheRouter’sWebInterface 14
ConfiguringwhichNMEAsente ncesaresent andwhentheyaresent
Toconfigurethetimeinterval,additionalprefixorIDinformation,andwhichNMEAsentencesthatcanbe
sent:
1. IntheIntervalfield,typetheamountoftime,inseconds,thatpassesbeforetheNMEAinformationis
sent.Thedefaultis10seconds.Therangeis1to255seconds.
2. Youca
nfurtheridentifytherouter—alsocalledaremoteasset—thatiscollectingandsendingtheGPS
information.Todoso:
AddIDTheIDisanuniqueremoteassetidentificationstring.TheIDstringcanbeanylengthupto20
characters,exceptthatthe&and$areinvalidcharacters.TheIDmustfollowthestandardNMEA
sentencestructure.RefertotheUniversalIPATCommandsReferenceGuideforsentencestructure.
ToaddmoreinformationtothebeginningoftheID,intheAddIDPrefixfield,typetheinformation.
3. YoucanselectwhichNMEAsentencetypesyouwanttosend.Todoso,checkthedesiredoptions:GCA,
GSA,GSV,GLL,RMC,andVTG.
Configuringthe serialport
Configuringtheserialport
ToconfiguretheserialterminalconnectedtotheRS232connectorDE9ontherouter:
1. FromSetup,selectSerialIPConfiguration.
2. Inthepanethatappears,checkEnabled.
3. FromtheBaudRatedropdownlist,selectthebaudrateatwhichtheserialterminalcommunicates.The
defaultis11
5200.
4. FromtheFlowControldropdownlist,selecttheflowcontrolfortheserialport.TheselectionsareNone
orRTSCTS.ThedefaultisNone.
5. FromtheParitydropdownlist,selecttheparityfortheserialport.TheselectionsareNone,Even,or
Odd.Thedefa
ultisNone.
6. TousetheModbusprotocolastheprotocoltheserialdevicesusetocommunicate,checkModbus.
7. FromtheDataBitsdropdownlist,selectthedatabitsfortheserialport.Databitselectionis7or8.The
defaultis8.
8. FromtheSto
pBitsdropdownlist,selectthestopbitsfortheserialport.Theselectionsare1or2.The
defaultis1.
Page view 13
1 2 ... 9 10 11 12 13 14 15 16 17 18 19 ... 37 38

Comments to this Manuals

No comments